Casestudy on a waste gas treatment project in flexible printed circuit(FPC)
Received Date:2021-03-23
Abstract:(FPC)company,the bag filter,activated carbon adsorption,lye scrubber,water scrubber,liquid caustic+ sodium hypochlorite ... Open+
Abstract:(FPC)company,the bag filter,activated carbon adsorption,lye scrubber,water scrubber,liquid caustic+ sodium hypochlorite scrubber were used to treat the exhaust gas.The total investment of the projectwas 2.7 million yuan,and the annual operation cost was 1.989 6 million yuan.The concentrations of sul⁃furic acid mist,hydrochloric acid mist,nitrogen oxides,formaldehyde,ammonia-containing exhaust gas,hydrogen cyanide,tin-containing exhaust gas,organic exhaust gas,and dust in the exhaust gas were 0~0.10 mg/m3,0.01~1.36 mg/m3,0~0.53 mg/m3,0.02~0.05 mg/m3,0.48~0.66 mg/m3,0.02~0.13mg/m3,0.75~2.35 mg/m3,0.846~2.505 mg/m3,and 1.47~2.56 mg/m3. Close-
Authors:
Units
- 1.Faculty of Environmental Science and Engineering,Kunming University of Science and Technology,Kunming 650500,China
- 2.Hangzhou Research Institute of China Coal Technology & Engineering Group,Hangzhou 311201,China
Keywords
- Flexible printed circuit
- Waste gas
- Treatment process
- Engineering example
Citation
YUAN Li,XU Xin.Case study on a waste gas treatment project in flexible printed circuit(FPC)[J].Energy Envi⁃ronmental Protection,2021,35(3):